Brand: IKUSI
IKUSI
Showing 61–95 of 95 results
-
Add to cart
IKUSI SCF-085. Ground-fixing “column” type. Heigh 90cm. Pipe of ?50mm. Base 200×200 mm
Features
Ground-fixing “column” type.
Heigh 90cm.
Pipe of ?50mm.
Base 200×200 mm?MANUAL/DATASHEET
-
Add to cart
IKUSI SPA-240. Wall-fixing ?U? type. Wind of the arm: 24 cm. Pipe of ?40 mm made of galvanized steel
Features
Wall-fixing ?U? type.
Wind of the arm: 24 cm.
Pipe of ?40 mm made of galvanized steel?MANUAL/DATASHEET
-
Add to cart
IKUSI SR-HTI. Accessories for HTI Headend. SR-HTI. Support to install the headend in a rack 19 ?.
Features
Accessories for HTI Headend. SR-HTI. Support to install the headend in a rack 19 ?.
??
MANUAL/DATASHEET
-
Ikusi SZB-180 Multi-channel amplifier UHF SZB
KSh16,618.00Add to cartIKUSI SZB-180. Modular Headend amplifier channel TV and Radio. TV amplifiers single-channels, multichannels, modulators and Sat-IF combiner ready for digital dividend.
Features
TV single-channel amplifiers, Z input de-multiplexing and Z output multiplexing. Adjacent channel operation allowed in UHF band.
FM Radio and DAB Amplifiers.
It is advisable to place the amplifiers on the base-plate following an increasing order of number of channel (frequency). The RF output of the headend will be taken from the last one of the modules ordered in this way.
Especially created for amplification of combined analog and digital channels.
Output voltage +24 VDC is automatically connected to the RF modules through a connecting bar at the base-plate.
Toolless mounting.
Technical specifications
REF. 2248
Bandwidth 2 UHF channels 3 UHF channels 4 UHF channels
Gain dB 60
Noise figure dB 5
Output level dB?V (2x) 118 (2x) 116 (2x) 115
Z Output return loss dB ? 6
Consumption mA 100
Dimensions mm 190 x 38 x 87?
MANUAL/DATASHEET
-
Ikusi SZB-214 Power supply 24,5A.
KSh13,756.00Add to cartIKUSI SZB-214. Power supply 4,5A.
Features
Electrical safety protection level: Class II. Mains lead with bipolar plug.
Output voltage is additionally available from two auxiliar jacks, for connection to one or two power inserters (mast-head amplifier remote powering). Banana jumper supplied.
Technical specifications
REF. 2250
Regulation type switch mode
Mains supply voltage (50/60 Hz) VAC 185 – 264
Output voltage VDC +24 (?)
Max output current A 4.5?
MANUAL/DATASHEET
-
Add to cart
This product is not sent to some countries or areas, if the cart does not have available carriers, you can contact us here
IKUSI TOR-150. Trestle-power 1.5m. Top end adapted for housing the point mast
Features
Trestle-power 1.5m.
Top end adapted for housing the point mast?MANUAL/DATASHEET
-
Add to cart
This product is not sent to some countries or areas, if the cart does not have available carriers, you can contact us here
IKUSI TOR-250. Trestle-power 2.5m. Top end adapted for housing the point mast
Features
Trestle-power 2.5m.
Top end adapted for housing the point mast?MANUAL/DATASHEET
-
Add to cart
IKUSI UAH-001. Bridge for connection of two bases BASK-500
Features
Bridge for connection of two bases BASK-500?
MANUAL/DATASHEET
-
Ikusi UDF-307 Splitter 3 outputs
KSh962.00Add to cartIKUSI UDF-307 . 2401 MHz indoor splitters UDF series.
Features
2400 MHz indoor splitters UDF series.
Technical specifications
REF. 2075 2076 2077 2078 2079
No. of ways 2 3 4 6 8
Insertion loss 5-862 MHz dB ? 3.6 ? 6.8 ? 8.1 ? 11.8 ? 11.9
950-1550 MHz ? 4.1 ? 8.5 ? 9.1 ? 13.5 ? 14.1
1551-2150 MHz ? 4.5 ? 9.7 ? 10.4 ? 15.1 ? 15.8
2151-2400 MHz ? 6 ? 10.1 ? 11 ? 15.1 ? 17
Output isolation 5-300 MHz dB ? 35 ? 25 ? 24 ? 28 ? 26
301-862 MHz ? 34 ? 25 ? 22 ? 25 ? 28
950-2400 MHz ? 20 ? 21 ? 22 ? 25 ? 28?
MANUAL/DATASHEET
-
Ikusi UDF-813 Splitter 8 outputs
KSh1,984.00Add to cartIKUSI UDF-813 . 2404 MHz indoor splitters UDF series.
Features
2400 MHz indoor splitters UDF series.
Technical specifications
REF. 2075 2076 2077 2078 2079
No. of ways 2 3 4 6 8
Insertion loss 5-862 MHz dB ? 3.6 ? 6.8 ? 8.1 ? 11.8 ? 11.9
950-1550 MHz ? 4.1 ? 8.5 ? 9.1 ? 13.5 ? 14.1
1551-2150 MHz ? 4.5 ? 9.7 ? 10.4 ? 15.1 ? 15.8
2151-2400 MHz ? 6 ? 10.1 ? 11 ? 15.1 ? 17
Output isolation 5-300 MHz dB ? 35 ? 25 ? 24 ? 28 ? 26
301-862 MHz ? 34 ? 25 ? 22 ? 25 ? 28
950-2400 MHz ? 20 ? 21 ? 22 ? 25 ? 28?
MANUAL/DATASHEET
-
Ikusi UDM-110 Tap 1 output 10 dB
KSh998.00Add to cartIKUSI UDM-110 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2052 2053 2054 2055
Outputs ? 1
Tap loss (? 0.7 dB) dB 10 15 20 25
Through loss 5-862 MHz dB ? 1.1 ? 1.0 ? 0.9 ? 0.5
950-2150 MHz ? 1.2 ? 1.7 ? 1.4 ? 1.5
2150-2400 MHz ? 2.8 ? 2.8 ? 2.7 ? 2.7
Directional isolation 5-300 MHz dB ? 29 ? 28 ? 31 ? 38
301-862 MHz ? 29 ? 27 ? 28 ? 35
950-2400 MHz ? 19 ? 23 ? 19 ? 24?
MANUAL/DATASHEET
-
Ikusi UDM-115 Tap 1 output 15 dB
KSh998.00Add to cartIKUSI UDM-115 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2052 2053 2054 2055
Outputs ? 1
Tap loss (? 0.7 dB) dB 10 15 20 25
Through loss 5-862 MHz dB ? 1.1 ? 1.0 ? 0.9 ? 0.5
950-2150 MHz ? 1.2 ? 1.7 ? 1.4 ? 1.5
2150-2400 MHz ? 2.8 ? 2.8 ? 2.7 ? 2.7
Directional isolation 5-300 MHz dB ? 29 ? 28 ? 31 ? 38
301-862 MHz ? 29 ? 27 ? 28 ? 35
950-2400 MHz ? 19 ? 23 ? 19 ? 24?
MANUAL/DATASHEET
-
Ikusi UDM-120 Tap 1 output 20 dB
KSh998.00Add to cartIKUSI UDM-120 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2052 2053 2054 2055
Outputs ? 1
Tap loss (? 0.7 dB) dB 10 15 20 25
Through loss 5-862 MHz dB ? 1.1 ? 1.0 ? 0.9 ? 0.5
950-2150 MHz ? 1.2 ? 1.7 ? 1.4 ? 1.5
2150-2400 MHz ? 2.8 ? 2.8 ? 2.7 ? 2.7
Directional isolation 5-300 MHz dB ? 29 ? 28 ? 31 ? 38
301-862 MHz ? 29 ? 27 ? 28 ? 35
950-2400 MHz ? 19 ? 23 ? 19 ? 24?
MANUAL/DATASHEET
-
Ikusi UDM-125 Tap 1 output 25 dB
KSh998.00Add to cartIKUSI UDM-125 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2052 2053 2054 2055
Outputs ? 1
Tap loss (? 0.7 dB) dB 10 15 20 25
Through loss 5-862 MHz dB ? 1.1 ? 1.0 ? 0.9 ? 0.5
950-2150 MHz ? 1.2 ? 1.7 ? 1.4 ? 1.5
2150-2400 MHz ? 2.8 ? 2.8 ? 2.7 ? 2.7
Directional isolation 5-300 MHz dB ? 29 ? 28 ? 31 ? 38
301-862 MHz ? 29 ? 27 ? 28 ? 35
950-2400 MHz ? 19 ? 23 ? 19 ? 24?
MANUAL/DATASHEET
-
Ikusi UDM-210 Tap 2 outputs 10 dB
KSh1,100.00Add to cartIKUSI UDM-210 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2056 2057 2058 2059
Outputs 2
Tap loss (? 0.7 dB) dB 10 15 20 25
Through loss 5-862 MHz dB ? 2.3 ? 1.6 ? 1.1 ? 1.1
950-2150 MHz ? 3.5 ? 2.5 ? 2.2 ? 2.3
2150-2400 MHz ? 4 ? 3.5 ? 3.3 ? 3.3
Directional isolation 5-300 MHz dB ? 26 ? 29 ? 31 ? 35
301-862 MHz ? 26 ? 27 ? 29 ? 32
950-2400 MHz ? 20 ? 22 ? 26 ? 28
Tap-to-tap isolation 5-300 MHz dB ? 38 ? 39 ? 46 ? 50
301-862 MHz ? 35 ? 37 ? 42 ? 45
950-2400 MHz ? 28 ? 37 ? 39 ? 35?
MANUAL/DATASHEET
-
Ikusi UDM-215 Tap 2 outputs 15 dB
KSh1,100.00Add to cartIKUSI UDM-215 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2056 2057 2058 2059
Outputs 2
Tap loss (? 0.7 dB) dB 10 15 20 25
Through loss 5-862 MHz dB ? 2.3 ? 1.6 ? 1.1 ? 1.1
950-2150 MHz ? 3.5 ? 2.5 ? 2.2 ? 2.3
2150-2400 MHz ? 4 ? 3.5 ? 3.3 ? 3.3
Directional isolation 5-300 MHz dB ? 26 ? 29 ? 31 ? 35
301-862 MHz ? 26 ? 27 ? 29 ? 32
950-2400 MHz ? 20 ? 22 ? 26 ? 28
Tap-to-tap isolation 5-300 MHz dB ? 38 ? 39 ? 46 ? 50
301-862 MHz ? 35 ? 37 ? 42 ? 45
950-2400 MHz ? 28 ? 37 ? 39 ? 35?
MANUAL/DATASHEET
-
Ikusi UDM-220 Tap 2 outputs 20 dB
KSh1,100.00Add to cartIKUSI UDM-220 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2056 2057 2058 2059
Outputs 2
Tap loss (? 0.7 dB) dB 10 15 20 25
Through loss 5-862 MHz dB ? 2.3 ? 1.6 ? 1.1 ? 1.1
950-2150 MHz ? 3.5 ? 2.5 ? 2.2 ? 2.3
2150-2400 MHz ? 4 ? 3.5 ? 3.3 ? 3.3
Directional isolation 5-300 MHz dB ? 26 ? 29 ? 31 ? 35
301-862 MHz ? 26 ? 27 ? 29 ? 32
950-2400 MHz ? 20 ? 22 ? 26 ? 28
Tap-to-tap isolation 5-300 MHz dB ? 38 ? 39 ? 46 ? 50
301-862 MHz ? 35 ? 37 ? 42 ? 45
950-2400 MHz ? 28 ? 37 ? 39 ? 35?
MANUAL/DATASHEET
-
Ikusi UDM-225 Tap 2 outputs 25 dB
KSh1,100.00Add to cartIKUSI UDM-225 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2056 2057 2058 2059
Outputs 2
Tap loss (? 0.7 dB) dB 10 15 20 25
Through loss 5-862 MHz dB ? 2.3 ? 1.6 ? 1.1 ? 1.1
950-2150 MHz ? 3.5 ? 2.5 ? 2.2 ? 2.3
2150-2400 MHz ? 4 ? 3.5 ? 3.3 ? 3.3
Directional isolation 5-300 MHz dB ? 26 ? 29 ? 31 ? 35
301-862 MHz ? 26 ? 27 ? 29 ? 32
950-2400 MHz ? 20 ? 22 ? 26 ? 28
Tap-to-tap isolation 5-300 MHz dB ? 38 ? 39 ? 46 ? 50
301-862 MHz ? 35 ? 37 ? 42 ? 45
950-2400 MHz ? 28 ? 37 ? 39 ? 35?
MANUAL/DATASHEET
-
Ikusi UDM-410 Tap 4 outputs 10 dB
KSh1,394.00Add to cartIKUSI UDM-410 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2060 2061 2062 2063
Outputs ? 4
Tap loss (? 1dB) dB 10 15 20 25
Through loss 5-862 MHz dB ? 4.0 ? 1.9 ? 0.9 ? 0.6
950-2150 MHz ? 4.8 ? 3.5 ? 2.8 ? 2.8
2150-2400 MHz ? 5.3 ? 4.2 ? 3.9 ? 3.4
Directional isolation 5-300 MHz dB ? 35 ? 30 ? 37 ? 37
301-862 MHz ? 33 ? 30 ? 33 ? 37
950-2400 MHz ? 29 ? 23 ? 25 ? 27
Tap-to-tap isolation 5-300 MHz dB ? 29 ? 30 ? 29 ? 30
301-862 MHz ? 26 ? 28 ? 26 ? 26
950-2400 MHz ? 24 ? 28 ? 24 ? 26?
MANUAL/DATASHEET
-
Ikusi UDM-415 Tap 4 outputs 15 dB
KSh1,394.00Add to cartIKUSI UDM-415 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2060 2061 2062 2063
Outputs ? 4
Tap loss (? 1dB) dB 10 15 20 25
Through loss 5-862 MHz dB ? 4.0 ? 1.9 ? 0.9 ? 0.6
950-2150 MHz ? 4.8 ? 3.5 ? 2.8 ? 2.8
2150-2400 MHz ? 5.3 ? 4.2 ? 3.9 ? 3.4
Directional isolation 5-300 MHz dB ? 35 ? 30 ? 37 ? 37
301-862 MHz ? 33 ? 30 ? 33 ? 37
950-2400 MHz ? 29 ? 23 ? 25 ? 27
Tap-to-tap isolation 5-300 MHz dB ? 29 ? 30 ? 29 ? 30
301-862 MHz ? 26 ? 28 ? 26 ? 26
950-2400 MHz ? 24 ? 28 ? 24 ? 26?
MANUAL/DATASHEET
-
Ikusi UDM-420 Tap 4 outputs 20 dB
KSh1,394.00Add to cartIKUSI UDM-420 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2060 2061 2062 2063
Outputs ? 4
Tap loss (? 1dB) dB 10 15 20 25
Through loss 5-862 MHz dB ? 4.0 ? 1.9 ? 0.9 ? 0.6
950-2150 MHz ? 4.8 ? 3.5 ? 2.8 ? 2.8
2150-2400 MHz ? 5.3 ? 4.2 ? 3.9 ? 3.4
Directional isolation 5-300 MHz dB ? 35 ? 30 ? 37 ? 37
301-862 MHz ? 33 ? 30 ? 33 ? 37
950-2400 MHz ? 29 ? 23 ? 25 ? 27
Tap-to-tap isolation 5-300 MHz dB ? 29 ? 30 ? 29 ? 30
301-862 MHz ? 26 ? 28 ? 26 ? 26
950-2400 MHz ? 24 ? 28 ? 24 ? 26?
MANUAL/DATASHEET
-
Ikusi UDM-425 Tap 4 outputs 25 dB
KSh1,394.00Add to cartIKUSI UDM-425 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2060 2061 2062 2063
Outputs ? 4
Tap loss (? 1dB) dB 10 15 20 25
Through loss 5-862 MHz dB ? 4.0 ? 1.9 ? 0.9 ? 0.6
950-2150 MHz ? 4.8 ? 3.5 ? 2.8 ? 2.8
2150-2400 MHz ? 5.3 ? 4.2 ? 3.9 ? 3.4
Directional isolation 5-300 MHz dB ? 35 ? 30 ? 37 ? 37
301-862 MHz ? 33 ? 30 ? 33 ? 37
950-2400 MHz ? 29 ? 23 ? 25 ? 27
Tap-to-tap isolation 5-300 MHz dB ? 29 ? 30 ? 29 ? 30
301-862 MHz ? 26 ? 28 ? 26 ? 26
950-2400 MHz ? 24 ? 28 ? 24 ? 26?
MANUAL/DATASHEET
-
Ikusi UDM-615 Tap 6 outputs 15 dB
KSh1,656.00Add to cartIKUSI UDM-615 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2064 2065 2066
Outputs ? 6
Tap loss (? 1dB) dB 15 20 25
Through loss 5-862 MHz dB ? 4.8 ? 4.8 ? 3.2
950-2150 MHz ? 5.7 ? 4.8 ? 3.8
2150-2400 MHz ? 7 ? 5 ? 4.3
Directional isolation 5-300 MHz dB ? 30 ? 37 ? 37
301-862 MHz ? 30 ? 33 ? 37
950-2400 MHz ? 23 ? 25 ? 27
Tap-to-tap isolation 5-300 MHz dB ? 30 ? 29 ? 30
301-862 MHz ? 28 ? 26 ? 26
950-2400 MHz ? 28 ? 24 ? 26?
MANUAL/DATASHEET
-
Ikusi UDM-620 Tap 6 outputs 20 dB
KSh1,656.00Add to cartIKUSI UDM-620 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2064 2065 2066
Outputs ? 6
Tap loss (? 1dB) dB 15 20 25
Through loss 5-862 MHz dB ? 4.8 ? 4.8 ? 3.2
950-2150 MHz ? 5.7 ? 4.8 ? 3.8
2150-2400 MHz ? 7 ? 5 ? 4.3
Directional isolation 5-300 MHz dB ? 30 ? 37 ? 37
301-862 MHz ? 30 ? 33 ? 37
950-2400 MHz ? 23 ? 25 ? 27
Tap-to-tap isolation 5-300 MHz dB ? 30 ? 29 ? 30
301-862 MHz ? 28 ? 26 ? 26
950-2400 MHz ? 28 ? 24 ? 26?
MANUAL/DATASHEET
-
Ikusi UDM-625 Tap 6 outputs 25 dB
KSh1,656.00Add to cartIKUSI UDM-625 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2064 2065 2066
Outputs ? 6
Tap loss (? 1dB) dB 15 20 25
Through loss 5-862 MHz dB ? 4.8 ? 4.8 ? 3.2
950-2150 MHz ? 5.7 ? 4.8 ? 3.8
2150-2400 MHz ? 7 ? 5 ? 4.3
Directional isolation 5-300 MHz dB ? 30 ? 37 ? 37
301-862 MHz ? 30 ? 33 ? 37
950-2400 MHz ? 23 ? 25 ? 27
Tap-to-tap isolation 5-300 MHz dB ? 30 ? 29 ? 30
301-862 MHz ? 28 ? 26 ? 26
950-2400 MHz ? 28 ? 24 ? 26?
MANUAL/DATASHEET
-
Ikusi UDM-815 Tap 8 outputs 15 dB
KSh1,874.00Add to cartIKUSI UDM-815 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2067 2068 2069
Outputs ? 8
Tap loss (? 1dB) dB 15 20 25
Through loss 5-862 MHz dB ? 4.3 ? 2.4 ? 2.2
950-2150 MHz ? 5.8 ? 5 ? 3.3
2150-2400 MHz ? 6 ? 5.5 ? 4.6
Directional isolation 5-300 MHz dB ? 30 ? 30 ? 33
301-862 MHz ? 30 ? 30 ? 36
950-2400 MHz ? 27 ? 23 ? 28
Tap-to-tap isolation 5-300 MHz dB ? 34 ? 30 ? 30
301-862 MHz ? 32 ? 28 ? 28
950-2400 MHz ? 25 ? 28 ? 28?
MANUAL/DATASHEET
-
Ikusi UDM-820 Tap 8 outputs 20 dB
KSh1,874.00Add to cartIKUSI UDM-820 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2067 2068 2069
Outputs ? 8
Tap loss (? 1dB) dB 15 20 25
Through loss 5-862 MHz dB ? 4.3 ? 2.4 ? 2.2
950-2150 MHz ? 5.8 ? 5 ? 3.3
2150-2400 MHz ? 6 ? 5.5 ? 4.6
Directional isolation 5-300 MHz dB ? 30 ? 30 ? 33
301-862 MHz ? 30 ? 30 ? 36
950-2400 MHz ? 27 ? 23 ? 28
Tap-to-tap isolation 5-300 MHz dB ? 34 ? 30 ? 30
301-862 MHz ? 32 ? 28 ? 28
950-2400 MHz ? 25 ? 28 ? 28?
MANUAL/DATASHEET
-
Ikusi UDM-825 Tap 8 outputs 25 dB
KSh1,874.00Add to cartIKUSI UDM-825 . UDM Taps 2400 MHz indoor multi-taps.
Features
1, 2, 4, 6 and 8 way shielded directional tap-offs.
Frequency range 5-2400 MHz.
DC tansit on the main line.
Technical specifications
REF. 2067 2068 2069
Outputs ? 8
Tap loss (? 1dB) dB 15 20 25
Through loss 5-862 MHz dB ? 4.3 ? 2.4 ? 2.2
950-2150 MHz ? 5.8 ? 5 ? 3.3
2150-2400 MHz ? 6 ? 5.5 ? 4.6
Directional isolation 5-300 MHz dB ? 30 ? 30 ? 33
301-862 MHz ? 30 ? 30 ? 36
950-2400 MHz ? 27 ? 23 ? 28
Tap-to-tap isolation 5-300 MHz dB ? 34 ? 30 ? 30
301-862 MHz ? 32 ? 28 ? 28
950-2400 MHz ? 25 ? 28 ? 28?
MANUAL/DATASHEET
-
Ikusi UEU-121K Individual LNB
KSh1,042.00Add to cartIKUSI UEU-121K. Satellite reception LNB Offset UEU Series
Features
UNIVERSAL, single output. Installation for a single receiver
Technical specifications
REF. 1113
Type UNIVERSAL
Input frequency GHz 10.70 – 12.75
Local oscillator GHz Low band 9.75
High band 10.60
Local Oscillator Temperature Drift (@ -40 ~ 60 ?C) MHz ? 3
Output frequency MHz 950 – 2150
Phase noise at 10 kHz dBc/Hz -80
Gain dB 60 (?2)
Noise figure typ dB 0,2
IF output ? 1
(VL or VH or HL or HH)
Control tone ? low band 0 Hz high band 22 kHz
Consumption mA 100
Reletive humidity % 0 – 95
Power supply VDC vert.: 11 – 14
hor.: 16 – 20?
MANUAL/DATASHEET
-
Ikusi UEU-124K Quattro LNB 4 polarities. 58dB
KSh5,016.00Add to cartIKUSI UEU-124K. Satellite reception LNB Offset UEU Series
Features
QUATTRO, four outputs with separate polarities for use with multiswitches
Technical specifications
REF. 1114
Type QUATTRO
Input frequency GHz 10.70 – 12.75
Local oscillator GHz Low band 9.75
High band 10.60
Local Oscillator Temperature Drift (@ -40 ~ 60 ?C) MHz ? 3
Output frequency MHz 950 – 2150
Phase noise at 10 kHz dBc/Hz -80
Gain dB 60 (?2)
Noise figure typ dB 0,2
IF output ? 4
(VL)?? (VH)?? (HL)?? (HH)
Control tone ? low band 0 Hz high band 22 kHz
Consumption mA 190
Reletive humidity % 0 – 95
Power supply VDC vert.: 11 – 14
hor.: 16 – 20?
MANUAL/DATASHEET
-
Ikusi UEU-221K Twin LNB 2 users. 58dB
KSh4,004.00Add to cartIKUSI UEU-221K. Satellite reception LNB Offset UEU Series
Features
?
TWIN, two direct outputs for two receivers
?
Technical specifications
REF. 3083
Type TWIN
Input frequency GHz 10.70 – 12.75
Local oscillator GHz Low band 9.75
High band 10.60
Local Oscillator Temperature Drift (@ -40 ~ 60 ?C) MHz ? 3
Output frequency MHz 950 – 2150
Phase noise at 10 kHz dBc/Hz -80
Gain dB 60 (?2)
Noise figure typ dB 0,2
IF output ? 2
(VL or VH or HL or HH)
Control tone ? low band 0 Hz high band 22 kHz
Consumption mA 190
Reletive humidity % 0 – 95
Power supply VDC vert.: 11 – 14
hor.: 16 – 20?
MANUAL/DATASHEET
-
Ikusi UEU-421K Quad LNB 4 users
KSh6,922.00Add to cartIKUSI UEU-421K. Satellite reception LNB Offset UEU Series
Features
UNIVERSAL, single output. Installation for a single receiver
TWIN, two direct outputs for two receivers
QUAD, four direct outputs for four receivers
QUATTRO, four outputs with separate polarities for use with multiswitches
Technical specifications
REF. 1113 3083 1112 1114
Type UNIVERSAL TWIN QUAD QUATTRO
Input frequency GHz 10.70 – 12.75
Local oscillator GHz Low band 9.75
High band 10.60
Local Oscillator Temperature Drift (@ -40 ~ 60 ?C) MHz ? 3
Output frequency MHz 950 – 2150
Phase noise at 10 kHz dBc/Hz -80
Gain dB 60 (?2)
Noise figure typ dB 0,2 0,2 0,2 0,2
IF output ? 1
(VL or VH or HL or HH) 2
(VL or VH or HL or HH) 4
(VL or VH or HL or HH) 4
(VL)?? (VH)?? (HL)?? (HH)
Control tone ? low band 0 Hz high band 22 kHz low band 0 Hz high band 22 kHz low band 0 Hz high band 22 kHz low band 0 Hz high band 22 kHz
Consumption mA 100 190 210 190
Reletive humidity % 0 – 95 0 – 95 0 – 95 0 – 95
Power supply VDC vert.: 11 – 14
hor.: 16 – 20 vert.: 11 – 14
hor.: 16 – 20 vert.: 11 – 14
hor.: 16 – 20 vert.: 11 – 14
hor.: 16 – 20MANUAL/DATASHEET
-
Add to cart
IKUSI USB-300. Accessories for HTI Headend. USB-300. USB-Ethernet adapter for local or remote control.
Features
Accessories for HTI Headend. USB-300. USB-Ethernet adapter for local or remote control.
Specifications
Conexiones Puerto Ethernet RJ-45 Ethernet (10/100/1000 Mbps) Conector USB Tipo A
LEDs Velocidad (naranja) Link/ACT (verde)
Est?ndares Especificaci?n USB Versi?n 3.0 Especificaci?n USB Versi?n 2.0 Especificaci?n USB Versi?n 1.1 Especificaci?n USB Versi?n 1.0
OHCI (Open Host Controller Interface) EHCI (Enhanced Host Controller Interface) IEEE 802.3 Ethernet
IEEE 802.3u 100BASE-T, TX, y compatible T4 Soporta modo suspensi?n y arranque remoto
Soporta full y half duplex en el modo gigabit Ethernet
DVB-T / DVB-C
General
Requisitos del Sistema Sistema Operativo: Microsoft Windows 8/7/Vista/XP SP3 Mac OS 10.6 a 10.8
Linux kernel 2.6.14x o superior
Gesti?n de Energ?a La gesti?n avanzada de energ?a reduce el consumo cuando no hay tr?fico o es escaso
F?sicas
Alimentaci?n Entrada: Por USB a 500 mA, 5 V DC Consumo: 150 mA, 3.3 V DC
Temperatura En uso: 0 a 45 ?C (32 a 113 ?F) Almacenado: -20 a 70 ?C (-4 a 158 ?F)
Humedad En uso: 10? a 90? sin condensaci?n Almacenado: 5? a 90? sin condensaci?n
Dimensiones 74.4 x 21 x 16 mm (2.93 x 0.83 x .063 pulgadas)
Peso 46.4 gramos (1.64 onzas)
Certificaciones CE FCC?
?
?
MANUAL/DATASHEET
-
Add to cart
IKUSI V-2T. 2 way splitters / 2 input combiners. Insertion loss: ? 4dB
Features
2 way splitters / 2 input combiners.
Insertion loss: ? 4dB
??
MANUAL/DATASHEET
-
Read more
This model replaces the LNB Inverto Black Premium Quad 40mm LTE 0.2dB (inverto-3311)
Specifically designed and selcted to address the demand of the global DTH market for a competitive and 4G/LTE protected solution, this LNB premium provides optimized reception capabilities using the latest chipset technology and waveguide design for satellite signal reception. It enables the reception of satellite TV and radio from a single satellite and its distribution to four single tuner Set-top boxes (or 2 twin tuner PVR). The LNB supports HD and UHD transmissions, delivers one-of-a-kind RF performances, very low power consumption and importantly engineered to mitigate interferences from 4G/LTE transmissions. Manufactured to the highest industry quality standards and engineered to meet strict specifications, this LNB is an ideal solution for the demanding customer of DTH operators and satellite broadcast reception across the world.
Features
Low Phase Noise, DVB-S2 (HD and UHD) compliant
Very low Noise Figure
Low power consumption
High Cross Polarization Isolation
High Frequency stability
Specifications
Input frequency range 10.7 GHz ~ 12.75 GHz
Output frequency range 950 MHz ~ 2150 MHz
Low band LO frequency 9.75 GHz
High band LO frequency 10.6 GHz
Noise figure 0.2 dB typ. (0.7 dB max.)
LO frequency accuracy @ 25? C ?500 kHz max.
LO temperature drift ?1.0 MHz max.
LO phase noise @ 10 kHz -80 dBc/Hz max.
Conversion gain 55 dB min.
Gain ripple (over 26 MHz bandwidth) ?0.6 dB
Gain variation (over full band) ?3 dB
Image rejection 40 dB min.
3th order intermodulation – ICP3 10 dBm min.
1 dB compression point (@ output) 0 dBm min.
Cross polarization isolation 22 dB typ., 20 dB min.
Control signal Ca (V) 11.0 V ~ 14.0 V
Control signal Cb (H) 16.0 V ~ 20.0 V
Control signal Cc (band switching) 22 kHz ?4 kHz, 0.4 V ~ 0.8 V pp
Output VSWR 2.5 : 1
In band spurious level -60 dBm max.
Current consumption 120 mA max. @ 11 VDC ~ 20 VDC
Operating temperature -35 ?C ~ +60 ?C
Output impedance (LNB2) 75 ?
Output connector type F-type (female)
Dish F/D ratio 0.6
Weight 221 g