Welcome to Alcatraz Dish Network Services!
SUPPORT 24/7/365!? +254720548999
SUPPORT 24/7/365!? +254720548999

Brand: IKUSI

IKUSI

Showing 61–95 of 95 results

  • IKUSI SCF-085. Ground-fixing “column” type. Heigh 90cm. Pipe of ?50mm. Base 200×200 mm

    Features
    Ground-fixing “column” type.
    Heigh 90cm.
    Pipe of ?50mm.
    Base 200×200 mm?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI SPA-240. Wall-fixing ?U? type. Wind of the arm: 24 cm. Pipe of ?40 mm made of galvanized steel

    Features
    Wall-fixing ?U? type.
    Wind of the arm: 24 cm.
    Pipe of ?40 mm made of galvanized steel?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI SR-HTI. Accessories for HTI Headend. SR-HTI. Support to install the headend in a rack 19 ?.

    Features
    Accessories for HTI Headend. SR-HTI. Support to install the headend in a rack 19 ?.
    ?

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI SZB-180. Modular Headend amplifier channel TV and Radio. TV amplifiers single-channels, multichannels, modulators and Sat-IF combiner ready for digital dividend.

    Features
    TV single-channel amplifiers, Z input de-multiplexing and Z output multiplexing. Adjacent channel operation allowed in UHF band.
    FM Radio and DAB Amplifiers.
    It is advisable to place the amplifiers on the base-plate following an increasing order of number of channel (frequency). The RF output of the headend will be taken from the last one of the modules ordered in this way.
    Especially created for amplification of combined analog and digital channels.
    Output voltage +24 VDC is automatically connected to the RF modules through a connecting bar at the base-plate.
    Toolless mounting.
    Technical specifications
    REF. 2248
    Bandwidth 2 UHF channels 3 UHF channels 4 UHF channels
    Gain dB 60
    Noise figure dB 5
    Output level dB?V (2x) 118 (2x) 116 (2x) 115
    Z Output return loss dB ? 6
    Consumption mA 100
    Dimensions mm 190 x 38 x 87

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI SZB-214. Power supply 4,5A.

    Features
    Electrical safety protection level: Class II. Mains lead with bipolar plug.
    Output voltage is additionally available from two auxiliar jacks, for connection to one or two power inserters (mast-head amplifier remote powering). Banana jumper supplied.
    Technical specifications
    REF. 2250
    Regulation type switch mode
    Mains supply voltage (50/60 Hz) VAC 185 – 264
    Output voltage VDC +24 (?)
    Max output current A 4.5

    ?

    MANUAL/DATASHEET

    Add to cart
  • This product is not sent to some countries or areas, if the cart does not have available carriers, you can contact us here

    IKUSI TOR-150. Trestle-power 1.5m. Top end adapted for housing the point mast

    Features
    Trestle-power 1.5m.
    Top end adapted for housing the point mast?

    MANUAL/DATASHEET

    Add to cart
  • This product is not sent to some countries or areas, if the cart does not have available carriers, you can contact us here

    IKUSI TOR-250. Trestle-power 2.5m. Top end adapted for housing the point mast

    Features
    Trestle-power 2.5m.
    Top end adapted for housing the point mast?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UAH-001. Bridge for connection of two bases BASK-500

    Features
    Bridge for connection of two bases BASK-500

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDF-307 . 2401 MHz indoor splitters UDF series.

    Features
    2400 MHz indoor splitters UDF series.
    Technical specifications
    REF. 2075 2076 2077 2078 2079
    No. of ways 2 3 4 6 8
    Insertion loss 5-862 MHz dB ? 3.6 ? 6.8 ? 8.1 ? 11.8 ? 11.9
    950-1550 MHz ? 4.1 ? 8.5 ? 9.1 ? 13.5 ? 14.1
    1551-2150 MHz ? 4.5 ? 9.7 ? 10.4 ? 15.1 ? 15.8
    2151-2400 MHz ? 6 ? 10.1 ? 11 ? 15.1 ? 17
    Output isolation 5-300 MHz dB ? 35 ? 25 ? 24 ? 28 ? 26
    301-862 MHz ? 34 ? 25 ? 22 ? 25 ? 28
    950-2400 MHz ? 20 ? 21 ? 22 ? 25 ? 28

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDF-813 . 2404 MHz indoor splitters UDF series.

    Features
    2400 MHz indoor splitters UDF series.
    Technical specifications
    REF. 2075 2076 2077 2078 2079
    No. of ways 2 3 4 6 8
    Insertion loss 5-862 MHz dB ? 3.6 ? 6.8 ? 8.1 ? 11.8 ? 11.9
    950-1550 MHz ? 4.1 ? 8.5 ? 9.1 ? 13.5 ? 14.1
    1551-2150 MHz ? 4.5 ? 9.7 ? 10.4 ? 15.1 ? 15.8
    2151-2400 MHz ? 6 ? 10.1 ? 11 ? 15.1 ? 17
    Output isolation 5-300 MHz dB ? 35 ? 25 ? 24 ? 28 ? 26
    301-862 MHz ? 34 ? 25 ? 22 ? 25 ? 28
    950-2400 MHz ? 20 ? 21 ? 22 ? 25 ? 28

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-110 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2052 2053 2054 2055
    Outputs ? 1
    Tap loss (? 0.7 dB) dB 10 15 20 25
    Through loss 5-862 MHz dB ? 1.1 ? 1.0 ? 0.9 ? 0.5
    950-2150 MHz ? 1.2 ? 1.7 ? 1.4 ? 1.5
    2150-2400 MHz ? 2.8 ? 2.8 ? 2.7 ? 2.7
    Directional isolation 5-300 MHz dB ? 29 ? 28 ? 31 ? 38
    301-862 MHz ? 29 ? 27 ? 28 ? 35
    950-2400 MHz ? 19 ? 23 ? 19 ? 24

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-115 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2052 2053 2054 2055
    Outputs ? 1
    Tap loss (? 0.7 dB) dB 10 15 20 25
    Through loss 5-862 MHz dB ? 1.1 ? 1.0 ? 0.9 ? 0.5
    950-2150 MHz ? 1.2 ? 1.7 ? 1.4 ? 1.5
    2150-2400 MHz ? 2.8 ? 2.8 ? 2.7 ? 2.7
    Directional isolation 5-300 MHz dB ? 29 ? 28 ? 31 ? 38
    301-862 MHz ? 29 ? 27 ? 28 ? 35
    950-2400 MHz ? 19 ? 23 ? 19 ? 24

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-120 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2052 2053 2054 2055
    Outputs ? 1
    Tap loss (? 0.7 dB) dB 10 15 20 25
    Through loss 5-862 MHz dB ? 1.1 ? 1.0 ? 0.9 ? 0.5
    950-2150 MHz ? 1.2 ? 1.7 ? 1.4 ? 1.5
    2150-2400 MHz ? 2.8 ? 2.8 ? 2.7 ? 2.7
    Directional isolation 5-300 MHz dB ? 29 ? 28 ? 31 ? 38
    301-862 MHz ? 29 ? 27 ? 28 ? 35
    950-2400 MHz ? 19 ? 23 ? 19 ? 24

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-125 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2052 2053 2054 2055
    Outputs ? 1
    Tap loss (? 0.7 dB) dB 10 15 20 25
    Through loss 5-862 MHz dB ? 1.1 ? 1.0 ? 0.9 ? 0.5
    950-2150 MHz ? 1.2 ? 1.7 ? 1.4 ? 1.5
    2150-2400 MHz ? 2.8 ? 2.8 ? 2.7 ? 2.7
    Directional isolation 5-300 MHz dB ? 29 ? 28 ? 31 ? 38
    301-862 MHz ? 29 ? 27 ? 28 ? 35
    950-2400 MHz ? 19 ? 23 ? 19 ? 24

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-210 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2056 2057 2058 2059
    Outputs 2
    Tap loss (? 0.7 dB) dB 10 15 20 25
    Through loss 5-862 MHz dB ? 2.3 ? 1.6 ? 1.1 ? 1.1
    950-2150 MHz ? 3.5 ? 2.5 ? 2.2 ? 2.3
    2150-2400 MHz ? 4 ? 3.5 ? 3.3 ? 3.3
    Directional isolation 5-300 MHz dB ? 26 ? 29 ? 31 ? 35
    301-862 MHz ? 26 ? 27 ? 29 ? 32
    950-2400 MHz ? 20 ? 22 ? 26 ? 28
    Tap-to-tap isolation 5-300 MHz dB ? 38 ? 39 ? 46 ? 50
    301-862 MHz ? 35 ? 37 ? 42 ? 45
    950-2400 MHz ? 28 ? 37 ? 39 ? 35

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-215 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2056 2057 2058 2059
    Outputs 2
    Tap loss (? 0.7 dB) dB 10 15 20 25
    Through loss 5-862 MHz dB ? 2.3 ? 1.6 ? 1.1 ? 1.1
    950-2150 MHz ? 3.5 ? 2.5 ? 2.2 ? 2.3
    2150-2400 MHz ? 4 ? 3.5 ? 3.3 ? 3.3
    Directional isolation 5-300 MHz dB ? 26 ? 29 ? 31 ? 35
    301-862 MHz ? 26 ? 27 ? 29 ? 32
    950-2400 MHz ? 20 ? 22 ? 26 ? 28
    Tap-to-tap isolation 5-300 MHz dB ? 38 ? 39 ? 46 ? 50
    301-862 MHz ? 35 ? 37 ? 42 ? 45
    950-2400 MHz ? 28 ? 37 ? 39 ? 35

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-220 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2056 2057 2058 2059
    Outputs 2
    Tap loss (? 0.7 dB) dB 10 15 20 25
    Through loss 5-862 MHz dB ? 2.3 ? 1.6 ? 1.1 ? 1.1
    950-2150 MHz ? 3.5 ? 2.5 ? 2.2 ? 2.3
    2150-2400 MHz ? 4 ? 3.5 ? 3.3 ? 3.3
    Directional isolation 5-300 MHz dB ? 26 ? 29 ? 31 ? 35
    301-862 MHz ? 26 ? 27 ? 29 ? 32
    950-2400 MHz ? 20 ? 22 ? 26 ? 28
    Tap-to-tap isolation 5-300 MHz dB ? 38 ? 39 ? 46 ? 50
    301-862 MHz ? 35 ? 37 ? 42 ? 45
    950-2400 MHz ? 28 ? 37 ? 39 ? 35

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-225 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2056 2057 2058 2059
    Outputs 2
    Tap loss (? 0.7 dB) dB 10 15 20 25
    Through loss 5-862 MHz dB ? 2.3 ? 1.6 ? 1.1 ? 1.1
    950-2150 MHz ? 3.5 ? 2.5 ? 2.2 ? 2.3
    2150-2400 MHz ? 4 ? 3.5 ? 3.3 ? 3.3
    Directional isolation 5-300 MHz dB ? 26 ? 29 ? 31 ? 35
    301-862 MHz ? 26 ? 27 ? 29 ? 32
    950-2400 MHz ? 20 ? 22 ? 26 ? 28
    Tap-to-tap isolation 5-300 MHz dB ? 38 ? 39 ? 46 ? 50
    301-862 MHz ? 35 ? 37 ? 42 ? 45
    950-2400 MHz ? 28 ? 37 ? 39 ? 35

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-410 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2060 2061 2062 2063
    Outputs ? 4
    Tap loss (? 1dB) dB 10 15 20 25
    Through loss 5-862 MHz dB ? 4.0 ? 1.9 ? 0.9 ? 0.6
    950-2150 MHz ? 4.8 ? 3.5 ? 2.8 ? 2.8
    2150-2400 MHz ? 5.3 ? 4.2 ? 3.9 ? 3.4
    Directional isolation 5-300 MHz dB ? 35 ? 30 ? 37 ? 37
    301-862 MHz ? 33 ? 30 ? 33 ? 37
    950-2400 MHz ? 29 ? 23 ? 25 ? 27
    Tap-to-tap isolation 5-300 MHz dB ? 29 ? 30 ? 29 ? 30
    301-862 MHz ? 26 ? 28 ? 26 ? 26
    950-2400 MHz ? 24 ? 28 ? 24 ? 26

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-415 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2060 2061 2062 2063
    Outputs ? 4
    Tap loss (? 1dB) dB 10 15 20 25
    Through loss 5-862 MHz dB ? 4.0 ? 1.9 ? 0.9 ? 0.6
    950-2150 MHz ? 4.8 ? 3.5 ? 2.8 ? 2.8
    2150-2400 MHz ? 5.3 ? 4.2 ? 3.9 ? 3.4
    Directional isolation 5-300 MHz dB ? 35 ? 30 ? 37 ? 37
    301-862 MHz ? 33 ? 30 ? 33 ? 37
    950-2400 MHz ? 29 ? 23 ? 25 ? 27
    Tap-to-tap isolation 5-300 MHz dB ? 29 ? 30 ? 29 ? 30
    301-862 MHz ? 26 ? 28 ? 26 ? 26
    950-2400 MHz ? 24 ? 28 ? 24 ? 26

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-420 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2060 2061 2062 2063
    Outputs ? 4
    Tap loss (? 1dB) dB 10 15 20 25
    Through loss 5-862 MHz dB ? 4.0 ? 1.9 ? 0.9 ? 0.6
    950-2150 MHz ? 4.8 ? 3.5 ? 2.8 ? 2.8
    2150-2400 MHz ? 5.3 ? 4.2 ? 3.9 ? 3.4
    Directional isolation 5-300 MHz dB ? 35 ? 30 ? 37 ? 37
    301-862 MHz ? 33 ? 30 ? 33 ? 37
    950-2400 MHz ? 29 ? 23 ? 25 ? 27
    Tap-to-tap isolation 5-300 MHz dB ? 29 ? 30 ? 29 ? 30
    301-862 MHz ? 26 ? 28 ? 26 ? 26
    950-2400 MHz ? 24 ? 28 ? 24 ? 26

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-425 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2060 2061 2062 2063
    Outputs ? 4
    Tap loss (? 1dB) dB 10 15 20 25
    Through loss 5-862 MHz dB ? 4.0 ? 1.9 ? 0.9 ? 0.6
    950-2150 MHz ? 4.8 ? 3.5 ? 2.8 ? 2.8
    2150-2400 MHz ? 5.3 ? 4.2 ? 3.9 ? 3.4
    Directional isolation 5-300 MHz dB ? 35 ? 30 ? 37 ? 37
    301-862 MHz ? 33 ? 30 ? 33 ? 37
    950-2400 MHz ? 29 ? 23 ? 25 ? 27
    Tap-to-tap isolation 5-300 MHz dB ? 29 ? 30 ? 29 ? 30
    301-862 MHz ? 26 ? 28 ? 26 ? 26
    950-2400 MHz ? 24 ? 28 ? 24 ? 26

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-615 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2064 2065 2066
    Outputs ? 6
    Tap loss (? 1dB) dB 15 20 25
    Through loss 5-862 MHz dB ? 4.8 ? 4.8 ? 3.2
    950-2150 MHz ? 5.7 ? 4.8 ? 3.8
    2150-2400 MHz ? 7 ? 5 ? 4.3
    Directional isolation 5-300 MHz dB ? 30 ? 37 ? 37
    301-862 MHz ? 30 ? 33 ? 37
    950-2400 MHz ? 23 ? 25 ? 27
    Tap-to-tap isolation 5-300 MHz dB ? 30 ? 29 ? 30
    301-862 MHz ? 28 ? 26 ? 26
    950-2400 MHz ? 28 ? 24 ? 26

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-620 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2064 2065 2066
    Outputs ? 6
    Tap loss (? 1dB) dB 15 20 25
    Through loss 5-862 MHz dB ? 4.8 ? 4.8 ? 3.2
    950-2150 MHz ? 5.7 ? 4.8 ? 3.8
    2150-2400 MHz ? 7 ? 5 ? 4.3
    Directional isolation 5-300 MHz dB ? 30 ? 37 ? 37
    301-862 MHz ? 30 ? 33 ? 37
    950-2400 MHz ? 23 ? 25 ? 27
    Tap-to-tap isolation 5-300 MHz dB ? 30 ? 29 ? 30
    301-862 MHz ? 28 ? 26 ? 26
    950-2400 MHz ? 28 ? 24 ? 26

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-625 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2064 2065 2066
    Outputs ? 6
    Tap loss (? 1dB) dB 15 20 25
    Through loss 5-862 MHz dB ? 4.8 ? 4.8 ? 3.2
    950-2150 MHz ? 5.7 ? 4.8 ? 3.8
    2150-2400 MHz ? 7 ? 5 ? 4.3
    Directional isolation 5-300 MHz dB ? 30 ? 37 ? 37
    301-862 MHz ? 30 ? 33 ? 37
    950-2400 MHz ? 23 ? 25 ? 27
    Tap-to-tap isolation 5-300 MHz dB ? 30 ? 29 ? 30
    301-862 MHz ? 28 ? 26 ? 26
    950-2400 MHz ? 28 ? 24 ? 26

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-815 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2067 2068 2069
    Outputs ? 8
    Tap loss (? 1dB) dB 15 20 25
    Through loss 5-862 MHz dB ? 4.3 ? 2.4 ? 2.2
    950-2150 MHz ? 5.8 ? 5 ? 3.3
    2150-2400 MHz ? 6 ? 5.5 ? 4.6
    Directional isolation 5-300 MHz dB ? 30 ? 30 ? 33
    301-862 MHz ? 30 ? 30 ? 36
    950-2400 MHz ? 27 ? 23 ? 28
    Tap-to-tap isolation 5-300 MHz dB ? 34 ? 30 ? 30
    301-862 MHz ? 32 ? 28 ? 28
    950-2400 MHz ? 25 ? 28 ? 28

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-820 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2067 2068 2069
    Outputs ? 8
    Tap loss (? 1dB) dB 15 20 25
    Through loss 5-862 MHz dB ? 4.3 ? 2.4 ? 2.2
    950-2150 MHz ? 5.8 ? 5 ? 3.3
    2150-2400 MHz ? 6 ? 5.5 ? 4.6
    Directional isolation 5-300 MHz dB ? 30 ? 30 ? 33
    301-862 MHz ? 30 ? 30 ? 36
    950-2400 MHz ? 27 ? 23 ? 28
    Tap-to-tap isolation 5-300 MHz dB ? 34 ? 30 ? 30
    301-862 MHz ? 32 ? 28 ? 28
    950-2400 MHz ? 25 ? 28 ? 28

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UDM-825 . UDM Taps 2400 MHz indoor multi-taps.

    Features
    1, 2, 4, 6 and 8 way shielded directional tap-offs.
    Frequency range 5-2400 MHz.
    DC tansit on the main line.
    Technical specifications
    REF. 2067 2068 2069
    Outputs ? 8
    Tap loss (? 1dB) dB 15 20 25
    Through loss 5-862 MHz dB ? 4.3 ? 2.4 ? 2.2
    950-2150 MHz ? 5.8 ? 5 ? 3.3
    2150-2400 MHz ? 6 ? 5.5 ? 4.6
    Directional isolation 5-300 MHz dB ? 30 ? 30 ? 33
    301-862 MHz ? 30 ? 30 ? 36
    950-2400 MHz ? 27 ? 23 ? 28
    Tap-to-tap isolation 5-300 MHz dB ? 34 ? 30 ? 30
    301-862 MHz ? 32 ? 28 ? 28
    950-2400 MHz ? 25 ? 28 ? 28

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UEU-121K. Satellite reception LNB Offset UEU Series

    Features
    UNIVERSAL, single output. Installation for a single receiver
    Technical specifications
    REF. 1113
    Type UNIVERSAL
    Input frequency GHz 10.70 – 12.75
    Local oscillator GHz Low band 9.75
    High band 10.60
    Local Oscillator Temperature Drift (@ -40 ~ 60 ?C) MHz ? 3
    Output frequency MHz 950 – 2150
    Phase noise at 10 kHz dBc/Hz -80
    Gain dB 60 (?2)
    Noise figure typ dB 0,2
    IF output ? 1
    (VL or VH or HL or HH)
    Control tone ? low band 0 Hz high band 22 kHz
    Consumption mA 100
    Reletive humidity % 0 – 95
    Power supply VDC vert.: 11 – 14
    hor.: 16 – 20

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UEU-124K. Satellite reception LNB Offset UEU Series

    Features
    QUATTRO, four outputs with separate polarities for use with multiswitches
    Technical specifications
    REF. 1114
    Type QUATTRO
    Input frequency GHz 10.70 – 12.75
    Local oscillator GHz Low band 9.75
    High band 10.60
    Local Oscillator Temperature Drift (@ -40 ~ 60 ?C) MHz ? 3
    Output frequency MHz 950 – 2150
    Phase noise at 10 kHz dBc/Hz -80
    Gain dB 60 (?2)
    Noise figure typ dB 0,2
    IF output ? 4
    (VL)?? (VH)?? (HL)?? (HH)
    Control tone ? low band 0 Hz high band 22 kHz
    Consumption mA 190
    Reletive humidity % 0 – 95
    Power supply VDC vert.: 11 – 14
    hor.: 16 – 20

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UEU-221K. Satellite reception LNB Offset UEU Series

    Features

    ?

    TWIN, two direct outputs for two receivers

    ?

    Technical specifications
    REF. 3083
    Type TWIN
    Input frequency GHz 10.70 – 12.75
    Local oscillator GHz Low band 9.75
    High band 10.60
    Local Oscillator Temperature Drift (@ -40 ~ 60 ?C) MHz ? 3
    Output frequency MHz 950 – 2150
    Phase noise at 10 kHz dBc/Hz -80
    Gain dB 60 (?2)
    Noise figure typ dB 0,2
    IF output ? 2
    (VL or VH or HL or HH)
    Control tone ? low band 0 Hz high band 22 kHz
    Consumption mA 190
    Reletive humidity % 0 – 95
    Power supply VDC vert.: 11 – 14
    hor.: 16 – 20

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI UEU-421K. Satellite reception LNB Offset UEU Series

    Features

    UNIVERSAL, single output. Installation for a single receiver

    TWIN, two direct outputs for two receivers

    QUAD, four direct outputs for four receivers

    QUATTRO, four outputs with separate polarities for use with multiswitches
    Technical specifications
    REF. 1113 3083 1112 1114
    Type UNIVERSAL TWIN QUAD QUATTRO
    Input frequency GHz 10.70 – 12.75
    Local oscillator GHz Low band 9.75
    High band 10.60
    Local Oscillator Temperature Drift (@ -40 ~ 60 ?C) MHz ? 3
    Output frequency MHz 950 – 2150
    Phase noise at 10 kHz dBc/Hz -80
    Gain dB 60 (?2)
    Noise figure typ dB 0,2 0,2 0,2 0,2
    IF output ? 1
    (VL or VH or HL or HH) 2
    (VL or VH or HL or HH) 4
    (VL or VH or HL or HH) 4
    (VL)?? (VH)?? (HL)?? (HH)
    Control tone ? low band 0 Hz high band 22 kHz low band 0 Hz high band 22 kHz low band 0 Hz high band 22 kHz low band 0 Hz high band 22 kHz
    Consumption mA 100 190 210 190
    Reletive humidity % 0 – 95 0 – 95 0 – 95 0 – 95
    Power supply VDC vert.: 11 – 14
    hor.: 16 – 20 vert.: 11 – 14
    hor.: 16 – 20 vert.: 11 – 14
    hor.: 16 – 20 vert.: 11 – 14
    hor.: 16 – 20

    MANUAL/DATASHEET

    Add to cart
  • IKUSI USB-300. Accessories for HTI Headend. USB-300. USB-Ethernet adapter for local or remote control.

    Features
    Accessories for HTI Headend. USB-300. USB-Ethernet adapter for local or remote control.
    Specifications
    Conexiones Puerto Ethernet RJ-45 Ethernet (10/100/1000 Mbps) Conector USB Tipo A
    LEDs Velocidad (naranja) Link/ACT (verde)
    Est?ndares Especificaci?n USB Versi?n 3.0 Especificaci?n USB Versi?n 2.0 Especificaci?n USB Versi?n 1.1 Especificaci?n USB Versi?n 1.0
    OHCI (Open Host Controller Interface) EHCI (Enhanced Host Controller Interface) IEEE 802.3 Ethernet
    IEEE 802.3u 100BASE-T, TX, y compatible T4 Soporta modo suspensi?n y arranque remoto
    Soporta full y half duplex en el modo gigabit Ethernet
    DVB-T / DVB-C
    General
    Requisitos del Sistema Sistema Operativo: Microsoft Windows 8/7/Vista/XP SP3 Mac OS 10.6 a 10.8
    Linux kernel 2.6.14x o superior
    Gesti?n de Energ?a La gesti?n avanzada de energ?a reduce el consumo cuando no hay tr?fico o es escaso
    F?sicas
    Alimentaci?n Entrada: Por USB a 500 mA, 5 V DC Consumo: 150 mA, 3.3 V DC
    Temperatura En uso: 0 a 45 ?C (32 a 113 ?F) Almacenado: -20 a 70 ?C (-4 a 158 ?F)
    Humedad En uso: 10? a 90? sin condensaci?n Almacenado: 5? a 90? sin condensaci?n
    Dimensiones 74.4 x 21 x 16 mm (2.93 x 0.83 x .063 pulgadas)
    Peso 46.4 gramos (1.64 onzas)
    Certificaciones CE FCC

    ?

    ?

    ?

    MANUAL/DATASHEET

    Add to cart
  • IKUSI V-2T. 2 way splitters / 2 input combiners. Insertion loss: ? 4dB

    Features
    2 way splitters / 2 input combiners.
    Insertion loss: ? 4dB
    ?

    ?

    MANUAL/DATASHEET

    Add to cart
  • This model replaces the LNB Inverto Black Premium Quad 40mm LTE 0.2dB (inverto-3311)

    Specifically designed and selcted to address the demand of the global DTH market for a competitive and 4G/LTE protected solution, this LNB premium provides optimized reception capabilities using the latest chipset technology and waveguide design for satellite signal reception. It enables the reception of satellite TV and radio from a single satellite and its distribution to four single tuner Set-top boxes (or 2 twin tuner PVR). The LNB supports HD and UHD transmissions, delivers one-of-a-kind RF performances, very low power consumption and importantly engineered to mitigate interferences from 4G/LTE transmissions. Manufactured to the highest industry quality standards and engineered to meet strict specifications, this LNB is an ideal solution for the demanding customer of DTH operators and satellite broadcast reception across the world.

    Features
    Low Phase Noise, DVB-S2 (HD and UHD) compliant
    Very low Noise Figure
    Low power consumption
    High Cross Polarization Isolation
    High Frequency stability
    Specifications
    Input frequency range 10.7 GHz ~ 12.75 GHz
    Output frequency range 950 MHz ~ 2150 MHz
    Low band LO frequency 9.75 GHz
    High band LO frequency 10.6 GHz
    Noise figure 0.2 dB typ. (0.7 dB max.)
    LO frequency accuracy @ 25? C ?500 kHz max.
    LO temperature drift ?1.0 MHz max.
    LO phase noise @ 10 kHz -80 dBc/Hz max.
    Conversion gain 55 dB min.
    Gain ripple (over 26 MHz bandwidth) ?0.6 dB
    Gain variation (over full band) ?3 dB
    Image rejection 40 dB min.
    3th order intermodulation – ICP3 10 dBm min.
    1 dB compression point (@ output) 0 dBm min.
    Cross polarization isolation 22 dB typ., 20 dB min.
    Control signal Ca (V) 11.0 V ~ 14.0 V
    Control signal Cb (H) 16.0 V ~ 20.0 V
    Control signal Cc (band switching) 22 kHz ?4 kHz, 0.4 V ~ 0.8 V pp
    Output VSWR 2.5 : 1
    In band spurious level -60 dBm max.
    Current consumption 120 mA max. @ 11 VDC ~ 20 VDC
    Operating temperature -35 ?C ~ +60 ?C
    Output impedance (LNB2) 75 ?
    Output connector type F-type (female)
    Dish F/D ratio 0.6
    Weight 221 g

    Read more