Tag: APC Smart-UPS VT 40kVA 400V SUVTP40KH4B4S UPS Kenya - Kenya

APC Smart-UPS VT 40kVA 400V SUVTP40KH4B4S UPS Kenya - Kenya

  • APC Smart-UPS VT 40kVA 400V SUVTP40KH4B4S UPS Kenya - Kenya

    APC Smart-UPS VT 40kVA 400V SUVTP40KH4B4S UPS Kenya 

    APC Smart-UPS VT 40kVA 400V SUVTP40KH4B4S UPS Kenya Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

     

    40kVA 400V SUVTP40KH4B4S UPS Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. APC Smart-UPS VT 40kVA Enables pre-installation UPS staging and testing and faster installation.

     

    APC Smart-UPS VT 40kVA Increases availability by allowing the UPS to be connected to two separate power sources. SUVTP40KH4B4S APC Smart-UPS VT 40kVA 400V w/4 Batt.

     

    Mod., Start-Up 5X8, Internal Maint Bypass, Parallel Capability Battery modules ship installed , Bolt down brackets , CD with software , Installation guide , Network Management Card , Power modules ship installed , Start up included , User.

    APC Smart-UPS VT 40kVA 400V w/4 Batt. Mod., Start-Up 5X8, Internal Maint Bypass, Parallel Capability

    Parallel-capacity capable
    Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
    Parallel-redundant capable
    Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy
    Smart-UPS VT Features & Benefits
    Availability
    Battery modules connected in parallel
    Delivers higher availability through redundant batteries.
    Automatic internal bypass
    Supplies utility power to the connected loads in the event of a UPS power overload or fault.
    Dual mains input
    Increases availability by allowing the UPS to be connected to two separate power sources.
    Generator compatible
    Ensures clean, uninterrupted power to protected equipment when generator power is used.
    Scalable runtime
    Allows additional run time to be quickly added as needed.
    Manageability
    Programmable frequency
    Ensures compatibility with different input frequencies.
    Audible alarms
    Provides notification of changing utility power and UPS power conditions
    LCD display
    Alpha-Numeric Display which displays system parameters and alarms.
    SmartSlot
    Customize UPS capabilities with management cards.
    InfraStruXure Manager Compatible
    Enables centralized management via the APC InfraStruXure Manager.
    Network manageable
    Provides remote power management of the UPS over the network.
    LED status indicators
    Quickly understand unit and power status with visual indicators.
    Total Cost of Ownership
    Temperature-compensated battery charging
    Prolongs battery life by regulating the charge voltage according to battery temperature.
    Manual maintenance bypass
    Reduces installation costs by eliminating the need for an external mechanical bypass.
    Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.
    Input power factor correction
    Minimizes installation costs by enabling the use of smaller generators and cabling.
    Sustainability
    EU CoC for UPS
    Ensures that UPSs sold in the EU are highly efficient
    Protection
    Cold-start capable
    Provides temporary battery power when the utility power is out.
    Safety-agency approved
    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
    Frequency and voltage regulation
    Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
    Marketing Features
    Hot-swappable batteries
    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
    Input power factor correction
    Minimizes installation costs by enabling the use of smaller generators and cabling.
    Dual mains input
    Increases availability by allowing the UPS to be connected to two separate power sources.
    Scalable runtime
    Allows additional run time to be quickly added as needed.
    Network manageable
    Provides remote power management of the UPS over the network.
    Manual maintenance bypass
    Reduces installation costs by eliminating the need for an external mechanical bypass.
    Serviceability
    Modular design
    Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
    Battery replacement without tools
    Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
    Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
    Shippable with modules installed
    Enables pre-installation UPS staging and testing and faster installation.
    40kva UPS Battery Backup specifications

    Output

    Output Power Capacity: 32.0 KW / 40.0 kVA
    Max Configurable Power (Watts): 32.0 KW / 40.0 kVA
    Nominal Output Voltage: 400V 3PH
    Output Voltage Note: Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
    Efficiency at Full Load: 95.8 %
    Output Voltage Distortion: Less than 5% at full load
    Output Frequency (sync to mains): 47 – 53 Hz for 50 Hz nominal
    Output Frequency (not synced): 50Hz +/- 0.1% for 50Hz nominal
    Other Output Voltages: 380, 415
    Crest Factor: 3 : 1
    Topology: Double Conversion Online
    Waveform Type: Sine wave
    Maximum Output Current: 64
    Bypass: Built-in Maintenance Bypass, Built-in Static Bypass

    Input

    Nominal Input Voltage: 400V 3PH
    Input Frequency: 40- 70 Hz (auto sensing)
    Input Connections: Hard Wire 5-wire (3PH + N + G)
    Input voltage range for main operations: 304 – 477 V
    Other Input Voltages: 380 , 415
    Efficiency at Full Load: 95.8 %
    Maximum Input Current: 55 A
    Input Power Factor at Full Load: 0.98

    Batteries & Runtime

    Battery Type: VRLA
    Included Battery Modules: 4
    Typical recharge time: 5 hour(s)
    Nominal Battery Voltage: +/-192 V (split battery referenced to neutral)
    Expected Battery Life (years): 3 – 5
    RBC Quantity: 4
    Extendable Run Time: 1
    End of Discharge Battery Voltage: +/-154 V

    Communications & Management

    Interface Port(s): DB-9 RS-232, Smart-Slot
    Pre-Installed SmartSlot™ Cards: AP9631
    Control panel: Multi-function LCD status and control console
    Audible Alarm: Audible and visible alarms prioritized by severity
    Emergency Power Off (EPO): Yes

    Physical

    Maximum Height: 1490.0 mm
    Maximum Width: 523.0 mm
    Maximum Depth: 842.0 mm
    Net Weight: 629.09kg
     
     

    Add to cart
Chat with us

Cart

Your Cart is Empty

Back To Shop