Mecer 30KVA 3 Phase Online Smart UPS
KSh680,000.00
Description
Mecer 30KVA 3 Phase Online Smart UPS
Mecer 30KVA 3 Phase Online Smart UPS from the leading mecer UPS authorised dealer in Nairobi Kenya, buy ME-30000- GTU 30KVA 3 Phase Online Smart UPS.
Microprocessor control optimizes reliability
Input power factor correction
Output power factor 0.8
Wide input voltage (110 V300 V)
Converter mode available
ECO mode for energy saving
Generator compatible
Charger capacity expansion to 6A for long-run models
Smart SNMP works well with either USB or RS-232 together
Comprehensive display allows easy monitoring and access of UPS status
Related products
-
Mecer Hybrid 5000VA 5000W Inverter Charger
KSh76,000.00Add to cartDescription
Mecer Hybrid 5000VA 5000W Inverter ChargerMecer Hybrid 5000VA 5000W Inverter Charger from the leading hybrid inverter dealer in Nairobi Kenya, buy online Mecer Hybrid 5000VA 5000W Inverter Charger and have it delivered. Mecer Hybrid 5000VA/5000W Inverter Charger 4000W MPPT 48V DC PF1 64V Battery Charger converts direct current (DC) from your batteries into alternating current (AC), Mecer Hybrid 5000VA 5000W Inverter Charger supplies your house with 220V alternating current. Generators are usually very noisy and run at constant speeds of typically 3600rpm to produce electricity.
Mecer Hybrid 5000VA 5000W Inverter Charger engine speed should remain constant to generate electricity. Have peace of mind with this Mecer inverter and start the process of saving.
Mecer Hybrid 5000VA 5000W Inverter specs
Pure sine wave inverter
Output power factor 1 (only 0.8 for 3KP/5KP Models)
Built-in battery equalization function to extend battery life cycle
Built-in MPPT solar charge controller
Selectable input voltage range for home appliances and personal computers
Selectable charging current based on applications
Configurable AC/Solar input priority via LCD setting
Compatible to mains voltage or generator power
Battery equalization for optimized battery performance and lifecycle
Parallel operation with up to 9 units only available for Axpert MKS 3KP/4KVA/5KVA*Specifications and features
RATED POWER 5000VA/ 5000W
Parallel Capability Yes, 9 units
INPUT Voltage 230 VAC
Selectable Voltage Range 170-280 VA
Frequency Range 50 Hz/60 Hz (Auto sensing)OUTPUT AC
Voltage Regulation (Batt. Mode) 230VAC ± 5%
Surge Power 10000VA
Efficiency (Peak) 93%
Transfer Time 10 ms – 20 ms
Waveform Pure sine waveBATTERY & AC CHARGER
Battery Voltage 48 VDC
Floating Charge Voltage 54 VDC Max: 58 VDC (Optional 64 VDC, please check with sales)
Overcharge Protection 60 VDC (Optional 66 VDC, please check with sales)SOLAR CHARGER & AC CHARGER
Maximum PV Array Power 4000W
MPPT Range @ Operating Voltage 60VDC ~115VDC
Maximum PV Array Open Circuit Voltage 145VDC
Maximum Solar Charge Current 80A
Maximum AC Charge Current 60A
Maximum Charge Current 140A
Maximum Efficiency 98%
Standby Power Consumption 2 WPHYSICAL
Dimension, D x W x H (mm) 100 x 272 x355
Net Weight (kgs) 13.5OPERATING ENVIRONMENT
Humidity 5% to 95% Relative Humidity(Non-condensing)
Operating Temperature 0°C to 55°C
Storage Temperature -15°C to 60°C -
Mecer 12V 7AH UPS Battery
KSh2,600.00Add to cartDescription
Mecer 12V 7AH UPS BatteryMecer 12V 7AH UPS Battery from the leading Mecer UPS replacement battery in Kenya, buy online and have the battery delivered at your doorstep, Mecer 12V 7AH UPS Battery.
12V 7AH Non spill able sealed,AGM System,Maintenance free battery,Lowself discharge,Long shelf life Nominal Capacity 20 hour:
rate (0.35A to 10.50V) 7Ah 10 hour
rate,(0.665A to 10.50V) 6.65Ah 5 hour
rate (1.19A to 10.20V) 5.95Ah 1 C (7A to 9.60V) 4.43Ah 3 C (21A to 9.60V) 2.8Ah 15 min rate (168W to 9.60V) 42W
Mecer UPS Battery -
Mecer 1KVA Smart UPS Rack Mount
KSh57,000.00Add to cartDescription
Mecer 1KVA Smart-UPS Rack MountMecer 1KVA Online UPS is designed for performers, 10KVA online UPS keeps the user working even when there is no power, we all know Kenya power is not reliable anyway.
Mecer 1KVA UPS has a lead time of more than 30 minutes hence the user will have adequate time to finish any unfished task. 1KVA mecer online UPS has a screen that helps the user to monitor the performance of the UPS, when on, off and the current status of the batteries. Mecer 1KVA smart UPS is rack-mountable hence it can be mounted in the server rack.
being mounted in a server rack increases the shelf life of the UPS as well as it security since the server rack would be under lock. Power disruption and power surges can be very costly for every business, with destruction to equipment to low production in a business resulting to fewer sales and poor customer satisfaction in case of service delivery organization that’s why we recommend .
Mecer 1KVA Online UPS Mtech networks is here to change that with Mecer 1KVA UPS that can help run small equipment up to 4 hours and also prevent them from being damaged by the power surge.
Mecer 1KVA smart UPS specifications
SKU ME-1000-WPTU
WEIGHT 9.8000
PHYSICAL DIMENSIONS 282 x 145 x 220 (mm)
CAPACITY 1000 VA / 800 W
VOLTAGE RANGE LOW LINE TRANSFER 160VAC/140VAC/120VAC/110VAC±5% ( based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
VOLTAGE RANGE LOW LINE COMEBACK 168VAC/148VAC/128VAC/118VAC ± 5 % ( based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
VOLTAGE RANGE HIGH LINE TRANSFER 300 VAC ± 5 %
VOLTAGE RANGE HIGH LINE COMEBACK 290 VAC ± 5 %
FREQUENCY RANGE 40Hz ~ 70 Hz
PHASE Single phase with ground
POWER FACTOR ** 0.99 @ nominal voltage (input voltage)
OUTPUT VOLTAGE 200/208/220/230/240VAC
AC VOLTAGE REGULATION (BATT. MODE) ±1% (Batt. Mode)
FREQUENCY RANGE (SYNCHRONIZED RANGE) 47 ~ 53 Hz or 57 ~ 63 Hz
FREQUENCY RANGE (BATT. MODE) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
OVERLOAD Sounding twice every second
CURRENT CREST RATIO 3:1
HARMONIC DISTORTION ** 3 % THD (linear load) ** 6 % THD (non-linear load)
WAVEFORM (BATT. MODE) Pure Sinewave
AC TO DC Zero
INVERTER TO BYPASS 4 ms (Typical)
AC MODE 87%
BATTERY MODE 83%
BATTERY TYPE 12 V / 9 AH
NUMBERS 2
RECHARGE TIME 4 hours recover to 90% capacity (Typical)
CHARGING CURRENT 1.0 A (max.)
CHARGING VOLTAGE 27.4 VDC ± 1%
BATTERY TYPE & NUMBERS No
CHARGING CURRENT No
CHARGING VOLTAGE No
HUMIDITY 20-90 % RH @ 0- 40°C (non-condensing)
NOISE LEVEL Less than 50dBA @ 1 Meter
OPTIONAL USB/RS-232 PORT Supports Windows® 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC
OPTIONAL SNMP Power management from SNMP manager and web browser
Run-times of ME-1000-WPTU 1kVA
Model Number of Batteries Encasement 100% Load Backup Time 75% Load Backup Time 50% Load Backup Time 25% Load Backup Time
ME-1000-WPTU 2 Internal 4 Minutes 6 Minutes 11 Minutes 24 Minutes -
Mercury 12V 9AH Elite 9I UPS Battery
KSh4,000.00Add to cartDescription
Mercury 12V 9AH Elite 9I UPS BatteryMercury 12V 9AH Elite 9I UPS Battery from the leading online shop in Nairobi Kenya, buy online and have it delivered.
Specifications
Nominal Voltage: 12 Volts
Nominal Capacity: 9 Amps
Weight: 2.70 Kilos
Peak power: 135 Amps 5Sec
Measurements: 150 x 65 x 95 mm (100 mm including terminals)
Charging voltage: 14.4 – 14.7 Volts
Float voltage: 13.5 – 13.62 Volts
Maximum charging current: 2.7 Amps
Enclosure: ABS
Connection terminal: Faston terminal 6.35 mm -
Mecer 2KVA Line Interactive UPS
KSh28,000.00Add to cartDescription
2KVA Mecer Line Interactive UPSMecer 2KVA Line Interactive UPS with AVR, Built-in Surge Protection, without Software (Optional USB Port) 1 x12V 7Ah battery will protect your most trusted assets from being damaged by a power surge, short circuit, and unreliable currents.
Mecer 2KVA UPS buy from Mtech Networks and have it delivered to you. we also sell replacements batteries for mecer UPS that is 12V 7AH UPS replacement battery at affordable prices.
2KVA Mecer UPS will keep you performing since the UPS gives you ample time to continue working even when there are power interruptions, Mecer 2KVA UPS has a lead time of more than 15 minutes which enables the user to conclude task started When used together with commercial batteries and inverters, Mecer UPS creates a very powerful and essential power backup for any organisations.
Mecer 2000VA UPS Specifications
Capacity: 2KVA (2000VA)
Technology: Line Interactive UPS.
Input Voltage: 220VAC
Input Voltage Range: 145VAC – 290VAC
Output Voltage: 220VAC ± 10%
Output Frequency: 50Hz/60Hz (Auto Sensing)
Transfer Time: < 10ms Waveform: Simulated Sine Wave Battery Type: Sealed Lead Acid (Maintenance-free) Battery Backup Time: Depends on load and battery capacity Recharge Time: 4-6 hours to 90% capacity Protection: Overload, Short Circuit, Surge, and Voltage Regulation Communication Ports: USB, RS232, SNMP (Optional). Software: Power Management Software included LCD Display: Provides real-time UPS status information Audible Alarms: Battery Low, Battery Disconnected, Overload, Fault Dimensions: Varies based on model Weight: Varies based on model Conclusions The Mecer ME-2000-VU Line Interactive 2KVA UPS is a reliable and efficient power backup solution for small to medium-sized applications. With a capacity of 2KVA (2000VA), it offers ample power to keep your critical equipment running during power outages or fluctuations. The line interactive UPS technology ensures effective voltage regulation and protection against power surges, spikes, and sags.







Reviews
There are no reviews yet.