Tripp Lite 2200VA SmartPro 230V 2.2kVA 1.6kW Line Interactive UPS Tower
KSh60,000.00
Description
Tripp Lite 2200VA SmartPro 230V 2.2kVA 1.6kW Line Interactive UPS Tower
Trip Lite 2200VA SmartPro 230V 2.2kVA 1.6kW Line Interactive UPS Tower from the leading UPS dealer in Nairobi Kenya, buy online Trip Lite 2200VA SmartPro 230V 2.2kVA 1.6kW Line Interactive UPS Tower and have it delivered Tripp Lite’s SMARTINT2200VS intelligent, line interactive tower uninterruptible power supply (UPS) prevents data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges.
Tripp Lite 2200VA SmartPro 230V 2.2kVA 1.6kW Line Interactive UPS Tower Large internal batteries offer 19 minutes half load runtime and 7 minutes at full load. Tripp Lite 2200VA SmartPro 230V 2.2kVA 1.6kW.
Line Interactive UPS Tower Maintains regulated 230V nominal output without using battery power during brownouts and overvoltages from 151 to 282V. 2200VA power handling capability offers compatibility with a variety of networking, telecom and other sensitive electronic applications.
UPC Code 037332120304
UPS Type Line-Interactive
INPUT
Rated input current (Maximum Load) 11.3A
Nominal Input Voltage(s) Supported 230V AC
UPS Input Connection Type C20 inlet
UPS Input Connection Description IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 2200
Output kVA Capacity (kVA) 2.20
Output Watt Capacity (Watts) 1600
Output kW Capacity (kW) 1.60
Power Factor 0.7
Nominal Voltage Details 230v inverter nominal output voltage
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) -19% +8%
Output Voltage Regulation (Battery Mode) +/- 5%
Included Output Power Cables Includes 3 C13 to C14 output power cables
Load Management Receptacles Three switchable two-outlet C13 load banks
Output Circuit Breakers 10A (x2) – each breaker protects 4 C13 outlets each, C19 is unbreakered
Hot-Swap PDU options PDUBHV20 (2U / 6 C13, 2 C19 outlets)
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Output Receptacles (8) C13; (1) C19
Individually Controllable Load Banks Yes
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 7 min. (1600w)
Half Load Runtime (min.) 19 min. (800w)
Expandable Runtime No
DC System Voltage (VDC) 48
Battery Recharge Rate (Included Batteries) Less than 4 hours from 10% to 90% (typical, full load discharge)
Battery Access Battery access door
Internal UPS Replacement Battery Cartridge RBC54
Battery Replacement Description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V
Overvoltage Correction Input voltages between 245 and 282 are reduced by 12%
Undervoltage Correction Input voltages between 177 and 199 are boosted by 14%
Severe Undervoltage Correction Input voltages between 151 and 176 are boosted by 30%
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 480
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Cooling Method Fan
Installation Form Factors Supported with Included Accessories Tower
Primary Form Factor Tower
Primary UPS Depth (mm) 305
Primary UPS Height (mm) 361
Primary UPS Width (mm) 234
Shipping Dimensions (hwd / cm) 49.02 x 38.61 x 40.39
Shipping Weight (kg) 27.49
UPS Housing Material Polycarbonate
UPS Power Module Dimensions (hwd, cm) 36.07 x 23.37 x 30.48
UPS Power Module Weight (kg) 24.49
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode Efficiency Rating (100% Load) 94%
Audible Noise Audible Noise < 47dBA At Front Side 1 Meter
COMMUNICATIONS
Network Management Cards SNMPWEBCARD ; TLNETCARD ; WEBCARDLX
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total)
PowerAlert Software For local monitoring via the UPSs built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable 2 USB and 2 DB9 cables included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Communications Interface Contact closure; DB9 Serial; Slot for SNMP/Web interface; USB
LINE / BATTERY TRANSFER
Transfer Time 2-4 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 151
High Voltage Transfer to Battery Power (Setpoint) 282
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Hot swappable batteries; Auto Probe Monitoring and Reboot (requires WEBCARDLX)
STANDARDS & COMPLIANCE
UPS Certifications CE; Meets FCC Part 15 Category A (EMI)
Certification Details CE 62040