Category: Mercury Online UPS
Mercury Online UPS
Showing all 4 results
-
Read more
Description
Mercury MP Pro 10k S Online UPS, 10KVA/10KW (1.0PF)
The Mercury MP Pro 10k S delivers enterprise-grade power protection through advanced online double conversion technology. This high-capacity UPS system provides uninterrupted 10KVA/10KW power output with unity power factor for critical infrastructure applications. Furthermore, the MP Pro 10k S incorporates sophisticated digital signal processing that ensures optimal power conditioning and seamless operation during utility fluctuations.
Advanced Double Conversion Technology
The Mercury MP Pro 10k S utilizes true online double conversion architecture that continuously converts AC input to DC, then regenerates clean AC output. Additionally, this technology provides complete isolation from utility power disturbances while maintaining zero transfer time during power transitions. The MP Pro 10k S delivers consistent power quality regardless of input conditions, protecting sensitive equipment from voltage variations, frequency fluctuations, and harmonic distortion.
High-Performance Power Output
Each MP Pro 10k S system delivers robust 10KVA/10KW capacity with 1.0 power factor for maximum load compatibility. Moreover, the unity power factor design ensures efficient power utilization across resistive and reactive loads. The Mercury MP Pro 10k S maintains stable output voltage and frequency regulation within tight tolerances, supporting demanding applications that require precise power specifications.
Intelligent Battery Management
The MP Pro 10k S features comprehensive 120VDC battery configuration utilizing 20 x 9AH/12V VRLA batteries for extended backup duration. Additionally, the system incorporates temperature compensation and intelligent charging algorithms that optimize battery performance and longevity. The Mercury MP Pro 10k S provides flexible battery configuration options with support for external battery expansion to meet specific runtime requirements.
Advanced Control and Communication
The MP Pro 10k S integrates sophisticated DSP control technology that continuously monitors power parameters and system status. Furthermore, the UPS includes RS232 and USB communication ports for comprehensive remote monitoring and management capabilities. The Mercury MP Pro 10k S supports SNMP integration and network management protocols, enabling seamless integration into existing IT infrastructure monitoring systems.
Comprehensive Protection Features
The MP Pro 10k S incorporates multiple protection mechanisms including overload, short circuit, overvoltage, undervoltage, and overtemperature safeguards. Additionally, the system features automatic restart functionality and periodic self-testing routines that ensure reliable operation. The Mercury MP Pro 10k S delivers surge protection, noise filtering, and power conditioning that exceeds industry standards for critical equipment protection.
Target Users
The Mercury MP Pro 10k S proves exceptionally suitable for specific user categories:
Data center operations – 10KVA/10KW capacity supports multiple server racks and networking equipment while the double conversion technology ensures zero downtime during power events
Critical IT infrastructure – Unity power factor and precise voltage regulation meet stringent requirements for enterprise servers, storage systems, and telecommunications equipment
Medical facilities – Continuous power conditioning and zero transfer time support life-critical medical devices that cannot tolerate power interruptions or quality variations
Industrial control systems – Robust protection features and extended battery backup ensure uninterrupted operation of automated manufacturing and process control equipmentTechnical Specifications
Power Performance
Output Capacity: 10KVA/10KW continuous operation
Power Factor: 1.0 (Unity power factor)
Input Phase: Single phase operation
Output Phase: Single phase operation
Technology: True online double conversion
Transfer Time: Zero milliseconds (continuous operation)Electrical Characteristics
Input Voltage Range: 160V-290V AC
Output Voltage: 220V/230V/240V AC ±1%
Output Frequency: 50Hz/60Hz ±0.1%
Efficiency: 92% at AC mode operation
Power Factor: >0.99 input power factor
THD: <3% total harmonic distortion Battery System Battery Configuration: 120VDC nominal voltage Battery Type: 20 x 9AH/12V VRLA batteries Backup Time: 5-13 minutes (varies by load) Charging Current: Intelligent temperature compensation Battery Test: Automatic periodic testing External Battery: Expandable configuration support Communication and Control Display: Digital LCD status panel Communication Ports: RS232 and USB interfaces Control Technology: Advanced DSP processing Remote Monitoring: SNMP protocol support Management Software: Windows/Linux compatible Alarm System: Audible and visual indicators Protection Standards Safety Certifications: IEC 62040 compliance Operating Temperature: 0°C to 40°C range Storage Temperature: -25°C to 70°C range Humidity Tolerance: 0-95% non-condensing Noise Level: <55dB at 1 meter distance -
Read more
Description
Mercury MP Pro 6k S Online UPS, 6KVA/6KW (1.0PF)
The Mercury MP Pro 6k S delivers professional-grade power protection through advanced online double conversion technology. This mid-capacity UPS system provides reliable 6KVA/6KW power output with unity power factor for critical business applications. Furthermore, the MP Pro 6k S incorporates sophisticated digital signal processing that ensures optimal power conditioning and seamless operation during utility disturbances.
True Online Double Conversion Technology
The Mercury MP Pro 6k S utilizes genuine online double conversion architecture that continuously transforms AC input to DC, then regenerates pristine AC output. Additionally, this technology provides complete isolation from utility power anomalies while maintaining zero transfer time during power transitions. The MP Pro 6k S delivers consistent power quality regardless of input conditions, protecting sensitive equipment from voltage sags, surges, and frequency variations.
Optimized Power Performance
Each MP Pro 6k S system delivers robust 6KVA/6KW capacity with 1.0 power factor for maximum efficiency across diverse load types. Moreover, the unity power factor design ensures optimal power utilization for both resistive and reactive loads. The Mercury MP Pro 6k S maintains precise output voltage regulation and frequency stability within tight tolerances, supporting demanding applications that require clean power specifications.
Advanced Battery Management System
The MP Pro 6k S features comprehensive 120VDC battery configuration utilizing 20 x 8.2AH/12V VRLA batteries for extended backup duration. Additionally, the system incorporates intelligent temperature compensation and charging algorithms that optimize battery performance and service life. The Mercury MP Pro 6k S provides flexible battery configuration options supporting 16, 18, or 20 battery setups to meet specific runtime requirements.
Intelligent Control and Monitoring
The MP Pro 6k S integrates advanced DSP control technology that continuously monitors power parameters and system performance. Furthermore, the UPS includes RS232 and USB communication ports for comprehensive remote monitoring and management capabilities. The Mercury MP Pro 6k S supports network integration and monitoring software, enabling seamless integration into existing IT infrastructure management systems.
Comprehensive Protection Mechanisms
The MP Pro 6k S incorporates multiple protection features including overload, short circuit, overvoltage, undervoltage, and overtemperature safeguards. Additionally, the system features automatic restart functionality and periodic self-testing routines that ensure reliable operation. The Mercury MP Pro 6k S delivers lightning protection, surge suppression, and power conditioning that exceeds industry standards for sensitive equipment protection.
Generator Compatibility and Cold Start
The MP Pro 6k S supports generator input operation and cold start functionality for enhanced versatility. Moreover, the system automatically adjusts to generator power characteristics while maintaining stable output performance. The Mercury MP Pro 6k S features wide input voltage range tolerance that accommodates varying generator output conditions without compromising power quality.
Target Users
The Mercury MP Pro 6k S proves exceptionally suitable for specific user categories:
Small to medium business operations – 6KVA/6KW capacity supports multiple workstations, servers, and networking equipment while unity power factor maximizes power efficiency
Network infrastructure environments – True online conversion and zero transfer time ensure uninterrupted operation of routers, switches, and communication systems
Server room applications – Advanced DSP control and precise voltage regulation meet stringent requirements for rack-mounted servers and storage systems
Critical equipment protection – Comprehensive protection features and extended battery backup support sensitive electronic devices that cannot tolerate power interruptionsTechnical Specifications
Power Performance
Output Capacity: 6KVA/6KW continuous operation
Power Factor: 1.0 (Unity power factor)
Input Phase: Single phase operation
Output Phase: Single phase operation
Technology: True online double conversion
Transfer Time: Zero milliseconds (continuous operation)Electrical Characteristics
Input Voltage Range: 100V-275V AC (adjustable)
Input Frequency: 40-70Hz auto-sensing
Output Voltage: 230V AC ±1%
Output Frequency: 50/60Hz ±3Hz synchronized
Efficiency: 92% at AC input mode
Harmonic Distortion: <2% THD output Crest Factor: 3:1 load capability Battery System Battery Configuration: 120VDC nominal voltage Battery Type: 20 x 8.2AH/12V VRLA batteries Backup Time: 7-20 minutes (varies by load) Battery Options: 16/18/20 battery configurations Charging: Temperature compensated charging Battery Test: Automatic periodic testing Physical Specifications Dimensions: 43.2cm (H) x 17.4cm (W) x 71.9cm (D) Weight: 60kg net weight Mounting: Rack-mountable with kit Noise Level: <55dB at 1 meter distance Operating Temperature: 0°C to 40°C range Storage Temperature: -25°C to 70°C range Communication and Control Display: Digital LCD status panel Communication Ports: RS232 and USB interfaces Control Technology: Advanced DSP processing Remote Monitoring: Network monitoring software Management Features: Cold start and generator compatibility Protection Standards: CE, EAC, IRAM, RCM, VDE certified -
Read more
Description
Double-Conversion Technology and PerformanceThe MPM 2K utilizes high-frequency double-conversion online architecture for continuous power conditioning. This technology converts incoming AC power to DC, then back to clean AC output. Consequently, connected equipment receives filtered power regardless of input quality variations.
Furthermore, the system operates with zero transfer time between utility and battery power. The online design eliminates switching delays that could disrupt sensitive equipment. Therefore, servers, networking hardware, and critical systems maintain uninterrupted operation during power fluctuations.
Power Capacity and Load Management
The Mercury MPM 2K provides 2000VA capacity with 1800W real power output through 0.9 power factor design. This configuration supports modern IT equipment with high power factor loads efficiently. Additionally, the system accommodates mixed loads including computers, servers, and telecommunications equipment.
Load monitoring displays real-time power consumption through the integrated LCD interface. The MPM 2K also includes overload protection with automatic bypass switching. Moreover, the system supports short-circuit protection and thermal management for extended operational life.
Battery System and Backup Duration
The MPM 2K incorporates 6 x 7AH/12V sealed lead-acid batteries in 72VDC configuration. These maintenance-free batteries provide extended backup duration based on connected load requirements. Additionally, intelligent battery management optimizes charging cycles and monitors battery health.
Smart charging technology employs multi-stage charging algorithms to maximize battery life. The system also features temperature compensation for optimal charging in varying environmental conditions. Furthermore, automatic battery testing identifies aging batteries before failure occurs.
Input and Output Specifications
The Mercury MPM 2K operates across wide input voltage ranges to accommodate unstable power conditions. The system features wide input voltage range capability for compatibility with varying utility conditions. Additionally, the MPM 2K maintains regulated output voltage regardless of input fluctuations.
Output voltage regulation maintains ±2% accuracy under varying load conditions. The system also provides pure sine wave output for compatibility with sensitive electronic equipment. Moreover, frequency regulation ensures stable 50/60Hz output regardless of input frequency variations.
Communication and Monitoring Features
The MPM 2K includes RS232 and USB communication interfaces for system monitoring and control. These connections enable integration with network management systems and monitoring software. Additionally, the system supports SNMP card installation for advanced network monitoring capabilities.
LCD human-computer interface provides detailed status updates and settings customization. The display shows real-time information including input/output voltages, load levels, and battery status. Furthermore, configurable alarms notify operators of system conditions requiring attention.
Protection Systems and Safety Features
Comprehensive protection systems safeguard both the UPS and connected equipment. The MPM 2K includes surge protection, EMI/RFI filtering, and lightning protection circuits. Additionally, the system monitors for input voltage anomalies and automatically compensates for power quality issues.
Emergency Power-Off (EPO) instantly shuts down the UPS during emergencies. The system also features input phase reversal detection and fan failure alarms. Moreover, thermal protection prevents overheating damage during high-load conditions.
Installation and Environmental Considerations
The Mercury MPM 2K supports tower installation with compact footprint requirements. The system operates efficiently in office environments with minimal noise generation. Additionally, the MPM 2K accommodates various environmental conditions within specified operating ranges.
Cooling systems automatically adjust fan speed based on load and temperature conditions. The system also includes dust filters to maintain internal component cleanliness. Furthermore, the compact design facilitates installation in space-constrained locations.
Ideal Users
The Mercury MPM 2K Online UPS suits specific applications particularly well:
Small data centers – True online double-conversion technology provides zero transfer time for server protection
Network operations centers – 72VDC battery system delivers extended backup time for critical networking equipment
Medical facilities – 0.9 power factor efficiency supports high-efficiency medical equipment with minimal power waste
Financial institutions – RS232/USB communication enables integration with monitoring systems for regulatory compliance
Manufacturing control systems – Wide input voltage range accommodates unstable industrial power conditions
Telecommunications providers – EMI/RFI filtering ensures clean power for sensitive communication equipment
Power Specifications
Capacity: 2000VA / 1800W
Power Factor: 0.9 (leading/lagging)
Technology: True online double-conversion
Transfer Time: 0ms (continuous operation)
Efficiency: >90% at optimal load
Overload Capability: 105-110% for 10 minutes, >130% immediate bypass
Input Characteristics
Voltage Range: Wide input acceptance (specific range software settable)
Frequency Range: 50/60Hz ±10% (±2.5% to ±20% software settable)
Power Factor: >0.98
Input Connection: Single phase with ground
Surge Protection: Built-in lightning and surge protection
EMI/RFI Filter: Integrated noise filtering
Output Performance
Voltage: 220/230/240VAC ±2%
Frequency: 50/60Hz ±0.2%
Waveform: Pure sine wave
Total Harmonic Distortion: <3% (linear load) Voltage Regulation: ±2% (0-100% load) Crest Factor: 3:1 maximum Battery System Configuration: 6 x 7AH/12V sealed lead-acid DC Voltage: 72VDC nominal Battery Life: 3-5 years (25°C ambient) Charging Method: Smart multi-stage charging Temperature Compensation: Automatic Battery Test: Automatic periodic testing Communication Interface Standard Connections: RS232, USB Optional: SNMP card, dry contact interfaces Monitoring Software: Compatible with standard UPS management Remote Control: EPO (Emergency Power Off) Display: LCD with status indicators Alarms: Audible and visual notifications Physical Specifications Form Factor: Tower design Installation: Desktop or floor standing Operating Temperature: 0°C to 40°C Storage Temperature: -15°C to 45°C Relative Humidity: 0-95% non-condensing Altitude: Up to 1000m (derated above) Protection Features Overload Protection: Automatic bypass switching Short Circuit Protection: Output and battery protection Over-temperature Protection: Thermal shutdown Battery Protection: Over/under voltage, over-current Input Protection: Surge, spike, and brownout protection Output Protection: Short circuit and overload -
Read more
Description
Advanced Double-Conversion ArchitectureThe MPM 3K utilizes high-frequency double-conversion online topology for continuous power conditioning. This technology converts incoming AC power to DC, then regenerates clean AC output with precise voltage and frequency control. Consequently, connected equipment receives filtered power regardless of utility power quality variations.
Furthermore, the system operates with zero transfer time between utility and battery power modes. The online design eliminates switching delays that could disrupt critical systems. Therefore, servers, telecommunications equipment, and network infrastructure maintain uninterrupted operation during power transitions.
Enhanced Power Capacity and Efficiency
The Mercury MPM 3K provides 3000VA capacity with 2700W real power output through 0.9 power factor design. This configuration efficiently supports modern IT equipment with high power factor loads. Additionally, the system accommodates mixed loads including servers, workstations, and networking equipment simultaneously.
Real-time load monitoring displays power consumption through the integrated LCD interface. The MPM 3K also includes intelligent overload management with automatic bypass switching. Moreover, the system features thermal management and fan speed control for optimal efficiency across varying load conditions.
Extended Battery System and Runtime
The MPM 3K incorporates 8 x 7AH/12V sealed lead-acid batteries in 96VDC configuration. These maintenance-free batteries provide extended backup duration based on connected load requirements. Additionally, advanced battery management optimizes charging cycles and continuously monitors battery health status.
Smart charging technology employs multi-stage charging algorithms with temperature compensation. The system also features automatic battery testing to identify aging batteries before failure. Furthermore, optional external battery packs extend runtime for extended outage protection.
Comprehensive Input and Output Management
The Mercury MPM 3K operates across wide input voltage ranges to accommodate unstable utility conditions. Input voltage range spans 115VAC±5 to 295VAC±5 for loads ≤70%, and 160VAC±5 to 295VAC±5 for loads ≥70%. Additionally, the system handles frequency variations from 46-54Hz (50Hz) and 56-64Hz (60Hz) with automatic sensing.
Output voltage regulation maintains 220/230VAC ±2% accuracy under varying load conditions. The system provides pure sine wave output with <3% total harmonic distortion for compatibility with sensitive electronics. Moreover, frequency regulation ensures stable 50/60Hz ±0.2% output regardless of input frequency variations. Advanced Communication and Monitoring The MPM 3K includes RS232 and USB communication interfaces for comprehensive system monitoring and control. These connections enable integration with network management systems and SNMP monitoring software. Additionally, the system supports optional SNMP card installation for advanced enterprise network monitoring capabilities. LCD display provides battery voltage display, load capacity display, and system status information. The interface shows real-time input/output voltages, load percentages, and battery status indicators. Furthermore, configurable alarms notify operators of system conditions requiring immediate attention. Comprehensive Protection and Safety Systems Multiple protection systems safeguard both the UPS and connected equipment from various power anomalies. The MPM 3K includes lightning and surge protection, short circuit and overload protection, and EMI/RFI noise filtering. Additionally, the system monitors input voltage anomalies and automatically compensates for power quality issues. Emergency Power-Off (EPO) function provides instant UPS shutdown during emergencies. The system also features input line and neutral reversal detection with alarm functionality. Moreover, comprehensive thermal protection prevents overheating damage during high-load operation. Flexible Installation and Environmental Adaptability The Mercury MPM 3K supports tower installation with compact footprint requirements for office environments. The system operates efficiently with automatic fan speed control based on load and temperature conditions. Additionally, the MPM 3K accommodates various environmental conditions within specified operating parameters. Fan speed auto control adjusts cooling based on load variations to minimize noise and extend component life. The system also includes dust filtration to maintain internal component cleanliness. Furthermore, the compact design facilitates installation in space-constrained server rooms and network closets. Cold Start and Startup Capabilities The MPM 3K features UPS startup without battery and cold start functionality. This capability allows system operation when batteries are disconnected or during initial commissioning. Additionally, the system supports generator input compatibility for backup power source integration. Automatic battery charge in UPS off mode ensures batteries remain fully charged even when the UPS is powered down. The system also provides maintenance-free operation with sealed battery technology. Moreover, intelligent charging algorithms extend battery service life through optimized charge cycles. Ideal Users The Mercury MPM 3K Online UPS suits specific applications particularly well: Medium data centers – True online double-conversion with zero transfer time protects server farms and storage systems Network operations centers – 96VDC battery system with 8x7AH capacity provides extended runtime for critical networking infrastructure Medical facilities – 0.9 power factor efficiency supports high-efficiency medical equipment while minimizing power consumption Financial institutions – RS232/USB/SNMP communication enables comprehensive monitoring for regulatory compliance requirements Manufacturing control systems – Wide input voltage range (115-295VAC) accommodates unstable industrial power conditions Telecommunications providers – EMI/RFI filtering and surge protection ensure clean power for sensitive communication equipment Power Specifications Capacity: 3000VA / 2700W Power Factor: 0.9 (leading/lagging) Technology: True online double-conversion Transfer Time: 0ms (continuous operation) Efficiency: >90% at optimal load
Input Power Factor: ≥0.97
Input Characteristics
Voltage Range: 115VAC±5 to 295VAC±5 (load ≤70%), 160VAC±5 to 295VAC±5 (load ≥70%)
Frequency Range: 46-54Hz (50Hz)±0.5Hz, 56-64Hz (60Hz)±0.5Hz auto-sensing
Phase: Single phase with neutral and ground
Surge Protection: Built-in lightning and surge protection
EMI/RFI Filter: Integrated noise filtering
Output Performance
Voltage: 220/230VAC ±2%
Frequency: 50/60Hz ±0.2%
Waveform: Pure sine wave
Total Harmonic Distortion: <3% (linear load) Voltage Regulation: ±2% (0-100% load) Overload Capability: Multiple protection levels Battery System Configuration: 8 x 7AH/12V sealed lead-acid DC Voltage: 96VDC nominal Battery Life: 3-5 years (25°C ambient) Charging Method: Smart multi-stage with temperature compensation Battery Test: Automatic periodic testing External Battery: Optional extension packs supported Communication Interface Standard Connections: RS232, USB Optional: SNMP card slot Monitoring Software: Compatible with standard UPS management Remote Control: EPO (Emergency Power Off) Display: LCD with voltage, load, and battery indicators Alarms: Input reversal detection, fan malfunction Physical Specifications Form Factor: Tower design Installation: Desktop or floor standing Operating Temperature: 0°C to 40°C Storage Temperature: -15°C to 45°C Relative Humidity: 0-95% non-condensing Cooling: Automatic fan speed control Protection Features Overload Protection: Automatic bypass and load shedding Short Circuit Protection: Output and battery circuits Over-temperature Protection: Thermal shutdown with alarm Battery Protection: Over/under voltage, over-current Input Protection: Surge, lightning, and brownout protection Network Protection: Fax/modem surge protection ports